Ensure technical documentation is both semantically correct and operationally precise: (1) use the exact product terms for what a setting applies to (scope/terminology), and (2) when describing component internals/graphs, specify the exact wiring rule for references (use the internal managing node, not an external component), aligned with the documented visibility constraints.
How to apply:
Example (Iteration internal wiring pattern):
:::danger IMPORTANT
To reference the created segments from an added internal component, add a **Reference** variable that equals **IterationItem** within the **Input** section of that internal component. There is no need to reference the corresponding external component, as the **IterationItem** component manages the loop of the workflow for all created segments.
:::
Example (setting scope/terminology):
The variables `MAX_CONTENT_LENGTH` in `/docker/.env` and `client_max_body_size` in `/docker/nginx/nginx.conf` set the file size limit for each upload to a dataset or **File**. These settings DO NOT apply in this scenario.